(ABC)Cables are several phase conductors insulated and tightly bundled together with bare/insulated neutral conductor for using in overhead power lines. Cable is primarily used for overhead service applications such as construction sites, outdoor or street lighting, etc. It is also used for electrical installations with alternating power networks with nominal voltage U0/U 0.6/1kV or in direct power networks with maximum voltage according to land 0.9kV.

Share:

SPECIFICATIONS

1.APPLIACATION: DISTRIBUTION LINE POWER NETWORKS

2.ELECTRICAL PERFORMANCE: 0.6/1kV

3.STANDARD: NFC

4.CORE IDENTIFICATION: BY COLOR STRIPE, BY RIB, BY NUMBER

5.CHEMICAL & UV & OIL RESISTANCE: GOOD

6.MINIMUM BENDING RADIUS: x15 CABLE DIAMETER

7.CORE: 3+1, 3+1+1, 3+1+2, 3+1+3

8.THERMAL PERFORMANCE
MAXIMUM SERVICE TEMPERATURE:90℃
MAXIMUM SHORT-CIRCUIT TEMPERATURE:250℃(max. 5s)
MINIMUM SERVICE TEMPERATURE:-20℃

9.INSTALLATION CONDITIONS: OPEN AIR, BURIED.

10. CABLE MARKING: OIL INK PRINTING, LASER PRINTING, EMBOSSING PRINTING

11. PACKAGING: BY ROLL, BY POLYWOOD OR WOODEN OR STEEL-WOODEN REEL/DRUM.

CONSTRUCTION

1. Phase Core

Conductor: Circular stranded, rounded, compacted aluminum conductor. Insulation: Black color Polyethylene(PE) or Cross-linked polyethylene(XLPE).

2.Neutral(Messenger) Core

Conductor: All Aluminum Alloy Conductor(AAAC).

Insulation: Black color Polyethylene(PE) or Cross-linked polyethylene(XLPE).

3. Street Lighting Core

Conductor: Circular stranded, rounded, compacted aluminum conductor.

Insulation: Black color Polyethylene(PE) or Cross-linked polyethylene(XLPE).

 

PARAMETER

AERIAL BUNDLED CABLE NFC 33-209

No. of Conductor and AreaPhase ConductorNeutral MessengerStreet Lighting ConductorApproximate Overall DiameterApproximate Cable Weight
Number of WiresNominal Diameter of Bare ConductorsNominal Thickness of InsulatingNominal Insulated Core DiameterNumber of WiresNominal Diameter of Bare ConductorsNominal Thickness of InsulatingNominal Insulated Core DiameterNumber of WiresNominal Diameter of Bare ConductorsNominal Thickness of InsulatingNominal Insulated Core Diameter
mm2Nos.mmmmmmNos.mmmmmmNos.mmmmmmmmkg/km
2×1674.81.27.214.2126
2×2576.0 1.48.817.6194
2×3577.0 1.610.220.4266
2×5078.11.611.322.6341
4×1674.81.27.217.2252
4×2576.0 1.48.821.2388
4×3577.0 1.610.224.6533
3×25+54.676.0 1.48.879.51.612.730514.1
3×25+54.6+1×1676.0 1.48.879.51.612.774.81.27.230580.7
3×25+54.6+2×1676.0 1.48.879.51.612.774.81.27.230647.3
3×25+54.6+3×1676.0 1.48.879.51.612.774.81.27.230713.8
3×35+54.677.0 1.610.279.51.612.733621.2
3×35+54.6+1×1677.0 1.610.279.51.612.774.81.27.233687.8
3×35+54.6+2×1677.0 1.610.279.51.612.774.81.27.233754.4
3×35+54.6+3×1677.0 1.610.279.51.612.774.81.27.233820.9
3×50+54.678.11.611.379.51.612.736735.0 
3×50+54.6+1×1678.11.611.379.51.612.774.81.27.236801.6
3×50+54.6+2×1678.11.611.379.51.612.774.81.27.236868.2
3×50+54.6+3×1678.11.611.379.51.612.774.81.27.236934.8
3×70+54.6129.91.813.579.51.612.737.5975.8
3×70+54.6+1×16129.91.813.579.51.612.774.81.27.237.51042.3
3×70+54.6+2×16129.91.813.579.51.612.774.81.27.237.51108.9
3×70+54.6+3×16129.91.813.579.51.612.774.81.27.237.51175.5
3×70+54.6+1×25129.91.813.579.51.612.776.0 1.48.8401077.3
3×70+54.6+2×25129.91.813.579.51.612.776.0 1.48.8401178.9
3×70+54.6+3×25129.91.813.579.51.612.776.0 1.48.8401280.4
3×70+N70129.91.813.5710.51.513.5411013.3
3×70+N70+1×16129.91.813.5710.51.513.574.81.27.2411079.9
3×70+N70+2×16129.91.813.5710.51.513.574.81.27.2411146.4
3×70+N70+3×16129.91.813.5710.51.513.574.81.27.2411213.0 
3×95+N701911.21.814.8710.51.513.5441196.2
3×95+N70+1×161911.21.814.8710.51.513.574.81.27.2441262.8
3×95+N70+2×161911.21.814.8710.51.513.574.81.27.2441329.3
3×95+N70+3×161911.21.814.8710.51.513.574.81.27.2441395.9
3×120+N701912.21.815.8710.51.513.5461350.5
3×120+N70+1×161912.21.815.8710.51.513.574.81.27.2461417.1
3×120+N70+2×161912.21.815.8710.51.513.574.81.27.2461483.7
3×120+N70+3×161912.21.815.8710.51.513.574.81.27.2461550.2
3×150+N701914.11.717.5710.51.513.5481660.9
3×150+N70+1×161914.11.717.5710.51.513.574.81.27.2481727.5
3×150+N70+2×161914.11.717.5710.51.513.574.81.27.2481794.0 
3×150+N70+3×161914.11.717.5710.51.513.574.81.27.2481860.6
3×120+N951912.21.815.81912.51.615.7471413.7
3×120+N95+1×161912.21.815.81912.51.615.774.81.27.2471480.3
3×120+N95+2×161912.21.815.81912.51.615.774.81.27.2471546.9
3×120+N95+3×161912.21.815.81912.51.615.774.81.27.2471613.4
3×150+N951914.11.717.51912.51.615.7491724.1
3×150+N95+1×161914.11.717.51912.51.615.774.81.27.2491790.7
3×150+N95+2×161914.11.717.51912.51.615.774.81.27.2491857.2
3×150+N95+3×161914.11.717.51912.51.615.774.81.27.2491923.3