Product Image Gallery for Elementor

All aluminum conductor (AAC conductor with AAC cable)

All Aluminum Conductor(AAC conductor with AAC cable) is also known as aluminum stranded conductor.

AAC conductors with AAC cable have good mechanical properties and electrical conductivity.

It is used in the construction of relatively short span distribution schemes and frequently applied for flexible busbar connections.

At its core, AAC conductor with AAC cable is a type of overhead electrical conductor made from aluminum alloy.

Unlike traditional copper conductors, which have been the go-to material for electrical transmission for decades, this offers several key advantages.

Share:

SPECIFICATIONS

1. APPLIACATION: DISTRIBUTION LINE POWER NETWORKS.

2. STANDARD: IEC 61089, ASTM B231, DIN 48201, AS 1531, BS 215 Part 1, BS EN 50182, GB/T.

3. INSTALLATION CONDITIONS: OPEN AIR

4. PACKAGING: BY ROLL, BY POLYWOOD OR WOODEN OR STEEL-WOODEN REEL/DRUM..

CONSTRUCTION

aac conductor, ACSR Conductor

1. Conductor

Hard drawn aluminum wire  

Generally, the AAC Conductor is formed by the following construction:

PARAMETER

ALL ALUMINIUM CONDUCTOR AS 1531

Code NumberActual 
Area
Stranding and Wire 
Diameter
Overall 
Diameter
Linear 
Mass
Nominal Breaking LoadMax. D.C. Resistance at 20℃
mm2No./mmmmkg/kmkNΩ/km
Leo34.47/2.507.50 94.3 5.70.8330 
Leonids41.67/2.758.25 113.0 6.70.6890 
Libra49.57/3.009.00 135.0 80.5790 
Mars77.37/3.7511.30 211.0 11.80.3700 
Mercury111.0 7/4.5013.50 304.0 16.90.2580 
Moon124.0 7/4.7514.30 339.0 18.90.2320 
Neptune158.0 19/3.2516.30 433.0 24.70.1830 
Orion183.0 19/3.5017.50 503.0 28.70.1570 
Pluto210.0 19/3.7518.80 576.0 31.90.1370 
Saturn262.0 37/3.0021.00 721.0 42.20.1100 
Sirius307.0 37/3.2522.80 845.0 48.20.0940 
Taurus337.0 19/4.7523.80 924.0 51.30.0857 
Triton409.0 37/3.7526.30 1120.0 62.20.0706 
Uranus506.0 61/3.2529.30 1400.0 75.20.0572 
Ursula587.0 61/3.5031.50 1620.0 87.30.0493 
Venus673.0 61/3.7533.80 1860.0 97.20.0429 

ALL ALUMINIUM CONDUCTOR ASTM B231

Code NameTotal AreaStranding and Wire DiameterOverall DiameterLinear 
Mass
Nominal Breaking LoadMax.D.C. Resistance at 20°C
AWG or MCMmm2No./mmmmkg/kmdaNΩ/km
Peachbell613.297/1.5544.67372492.1692
Rose421.167/1.9615.89583961.3624
Iris233.617/2.4747.42935970.8577
Pansy142.397/2.7768.331177320.6801
Poppy1/053.487/3.1199.361478730.539
Aster2/067.427/3.50310.5118611000.4276
Phlox3/085.037/3.93211.80 23413470.339
Oxlip4/0107.237/4.41713.2629616980.2688
Valerian250126.7119/2.91314.5734920620.2275
Sneezewort250126.717/4.8014.40 34920070.2275
Laurel266.8135.1619/3.0115.0537322000.2133
Daisy266.8135.167/4.9614.90 37321410.2133
Peony300152.0 19/3.19315.9741924030.1896
Tulip336.4170.4519/3.38116.9147026950.1691
Daffodil350177.3519/3.44717.2448928040.1625
Canna397.5201.4219/3.67318.3655531840.1431
Goldentuft45022819/3.90919.5562934990.1264
Syringa477241.6837/2.88220.1966638490.1193
Cosmos477241.6819/4.02320.1266637080.1193
Hyacinth500253.3537/2.95120.6569840350.1138
Zinnia500253.3519/4.1220.669838880.1138
Dahlia556.528219/4.34621.7377743270.1022
Mistletoe556.528237/3.11421.7977743620.1022
Meadowsweet60030437/3.23322.6383847030.0948
Orchid636322.2537/3.3323.3188849850.0894
Heuchera650329.3537/3.36623.5690850950.0875
Flag700354.7161/2.7224.4897851460.0813
Verbena700354.7137/3.49324.4597854870.0813

ALL ALUMINIUM CONDUCTOR BS EN 50182

Code NumberActual 
Area
Stranding and Wire 
Diameter
Overall 
Diameter
Linear 
Mass
Nominal Breaking LoadMax. D.C. Resistance at 20℃
mm2No./mmmmkg/kmkNΩ/km
Gnat26.97/2.216.63 73.0 4.81.0643 
Mosquito36.97/2.597.77 101.0 6.30.7749 
Ladybird42.87/2.798.37 117.0 7.30.6678 
Bluebottle73.67/3.6610.98 201.0 11.80.3880 
Earwig78.67/3.7811.34 215.0 12.60.3638 
Grasshopper84.17/3.9111.73 230.0 13.50.3400 
Clegg95.67/4.1712.51 261.0 15.30.2989 
Beetle106.419/2.6713.35 292.0 18.10.2701 
Bee1327/4.9014.70 361.0 21.10.2165 
Caterpillar185.919/3.5317.65 511.0 29.80.1546 
Spider237.619/3.9919.95 653.0 38.0 0.1210 
Moth373.119/5.0025.00 1025.0 59.70.0770 
Drone372.437/3.5825.06 1027.0 59.60.0774 
Maybug486.137/4.0928.63 1341.0 77.80.0593 
Scorpion529.837/4.2729.89 1461.0 84.80.0544 
Cicada628.337/4.6532.55 1733.0 100.50.0459 

ALL ALUMINIUM CONDUCTOR BS 215 Part 1

Code nameNominal Aluminum 
Area
Stranding and Wire 
Diameter
Sectional 
Area
Overall 
Diameter
Linear 
Mass
Max. D.C. Resistance at 20℃Rated 
Strength
Final 
Modulus of Elasticity
mm2No./mmmm2mmkg/kmΩ/kmdaNhbar
Midge227/2.0623.336.18641.2273995900
Aphis253/3.3526.47.2731.0814115900
Gnat257/2.2126.86.6731.0664595900
Weevil303/3.6631.67.9860.90824865900
Mosquito357/2.59377.81010.77626035900
Ladybird407/2.7942.88.41170.66896875900
Ant507/3.1052.839.30 1450.54198285900
Fly607/3.4063.5510.20 1740.45059905900
Bluebottle707/3.6673.711.0 2020.388111345900
Earwig757/3.7878.511.42150.364411945900
Grasshopper807/3.9184.111.72300.340612785900
Clegg907/4.1795.612.52620.299414535900
Wasp1007/4.3910613.172900.270216005900
Beetle10019/2.6710613.42930.270417425600
Bee1257/4.9013214.73610.216919445600
Cricket1507/5.36157.916.14320.181823855600
Hornet15019/3.25157.616.254340.182525705600
Caterpillar17519/3.5318617.75120.154728635600
Chafer20019/3.78213.218.95870.134932405600
Spider22519/3.99236.920.0 6520.121136015600
Cockroach25019/4.22265.721.10 7310.108340405600
Butterfly30019/4.65322.723.258880.0891648755600
Moth35019/5.00373.225.0 10270.0771156375600
Drone35037/3.58373.325.110290.0774157455600
Locust40019/5.36428.526.811790.067164735600
Centipede40037/3.78415.226.4611450.0694463105600
Maybug45037/4.09486.928.613420.0593174015600
Scorpion50037/4.27529.529.914600.0544179985600
Cicada60037/4.65628.632.617330.0458894955600
Tarantula75037/5.23794.636.621910.03627120105600

ALL ALUMINIUM CONDUCTOR DIN 48201

Code NumberActual 
Area
Stranding and Wire 
Diameter
Overall 
Diameter
Linear 
Mass
Nominal Breaking LoadMax. D.C. 
Resistance  at 20℃
mm2mm2No./mmmmkg/kmdaNΩ/km
1615.897/1.705.1442901.8018
2524.257/2.106.3674251.1808
3534.367/2.507.5945850.8332
5049.487/3.009.0 1358100.5786
5048.3619/1.809.0 1338600.5950 
7065.8219/2.1010.518111500.4371
9593.2719/2.5012.525615950.3084
120117.00 19/2.8014.0 32219100.2459
150147.10 37/2.2515.240625700.196
185181.60 37/2.5017.550131050.1587
240242.5461/2.2520.267040150.0091
300299.4361/2.5022.582748500.0965
400400.1461/2.8926.0 110561900.07221
500499.8361/3.2329.1138176000.05781
625626.20 91/2.9632.6173396900.04625
800802.10 91/3.3536.82219120550.03611
1000999.7191/3.7441.12766148450.0289

ALL ALUMINIUM CONDUCTOR GB/T

Nominal areaActual 
Area
Stranding and Wire 
Diameter
Overall 
Diameter
Linear 
Mass
Nominal Breaking LoadMax. D.C. Resistance at 20℃
mm2mm2No./mmmmkg/kmkNΩ/km
3534.367/2.507.50 94.0 6.010.8333 
5049.487/3.009.00 135.3 8.410.5787 
7071.257/3.6010.80 194.9 11.40 0.4020 
9595.147/4.1612.50 260.2 15.220.3010 
120121.2119/2.8514.3 333.2 20.610.2374 
150148.0719/3.1515.8 407.0 24.430.1943 
185182.80 19/3.5017.5 502.4 30.160.1574 
210209.8519/3.7518.8 576.8 33.580.1371 
240238.7637/4.0020.0 656.3 38.20 0.1205 
300297.5737/3.2022.4 819.8 49.10 0.0969 
500502.90 37/4.1629.1 1385.5 80.460.0573 

ALL ALUMINIUM CONDUCTOR IEC 61089

Code NumberActual 
Area
Number of WiresDiameterLinear 
Mass
Rated StrengthMax. D.C. Resistance at 20℃
WireCond.
mm2No.mmmmkg/kmkNΩ/km
101071.35 4.05 27.41.95 2.8633
161671.71 5.12 43.83.04 1.7896
252572.13 6.40 68.44.50 1.1453
404072.70 8.09 109.46.80 0.7158
636373.39 10.20 172.310.39 0.4545 
100100192.59 12.90 274.817.00 0.2877
125125192.89 14.50 343.621.25 0.2302
160160193.27 16.40 439.826.40 0.1798
200200193.66 18.30 549.732.00 0.1439
250250194.09 20.50 687.140.00 0.1151
315315373.29 23.00 867.951.97 0.0916
400400373.71 26.00 110564.00 0.0721
450450373.94 27.50 1239.872.00 0.0641
500500374.15 29.00 1377.680.00 0.0577
560560374.39 30.70 1542.989.60 0.0515
630630613.63 32.60 1738.3100.80 0.0458
710710613.85 34.60 1959.1113.60 0.0407
800800614.09 36.80 2207.4128.00 0.0361
900900614.33 39.00 2483.3144.00 0.0321
10001000614.57 41.10 2759.2160.00 0.0289
11201120913.96 43.50 3093.5179.20 0.0258
12501250914.18 46.00 3452.6200.00 0.0231
14001400914.43 48.70 3866.9224.00 0.0207
15001500914.58 50.40 4143.1240.00 0.0193

INQUIRY

Please Feel free to give your inquiry in the form below.we will reply you in 24 hours.

滚动至顶部